Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
J Clin Med ; 13(4)2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38398423

RESUMO

This review provides a detailed analysis of hemodiafiltration (HDF), its progress from an emerging technique to a potential conventional treatment for chronic hemodialysis patients, and its current status. The article covers the advances, methods, and clinical benefits of HDF, specifically focusing on its impact on cardiovascular health, survival rates, and overall well-being. The review also addresses questions about the safety of HDF and provides evidence to dispel concerns related to the elimination of beneficial substances and infection risks. Additionally, the article explores the potential implications of expanded hemodialysis (HDx) as an alternative to HDF, its classification, safety profile, and an ongoing trial assessing its non-inferiority to HDF. Supported by evidence from randomized controlled trials and observational studies, the review emphasizes the superiority of HDF as a hemodialysis modality and advocates for its positioning as the gold standard in treatment. However, it acknowledges the need for extensive research to define the role of HDx in comprehensive treatment approaches in individuals undergoing dialysis. The synthesis of current knowledge underscores the importance of ongoing exploration and research to refine hemodialysis practices for optimal patient outcomes.

2.
Artif Organs ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38404240

RESUMO

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, κFLC, prolactin, α1 -microglobulin, α1 -acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2 -microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1 -microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.

5.
Blood Purif ; 53(5): 343-357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38109873

RESUMO

During the last decades, various strategies have been optimized to enhance clearance of a variable spectrum of retained molecules to ensure hemodynamic tolerance to fluid removal and improve long-term survival in patients affected by kidney failure. Treatment effects are the result of the interaction of individual patient characteristics with device characteristics and treatment prescription. Historically, the nephrology community aimed to provide adequate treatment, along with the best possible quality of life and outcomes. In this article, we analyzed blood purification techniques that have been developed with their different characteristics.


Assuntos
Injúria Renal Aguda , Hemodiafiltração , Hemofiltração , Falência Renal Crônica , Humanos , Hemofiltração/métodos , Diálise Renal/métodos , Qualidade de Vida , Hemodiafiltração/métodos , Falência Renal Crônica/terapia , Injúria Renal Aguda/terapia , Injúria Renal Aguda/etiologia
6.
Clin Kidney J ; 16(11): 2174-2184, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37915889

RESUMO

Background: The number of frail patients of advanced age with end-stage kidney disease (ESKD) undergoing hemodialysis is increasing globally. Here we evaluated a frailty screening program of ESKD patients starting hemodialysis, and subsequent multidisciplinary interventions. Methods: This was a prospective observational study of ESKD patients in a hemodialysis program. Patients were evaluated for frailty (Fried frail phenotype) before and after a 12-month period. Patients followed standard clinical practice at our hospital, which included assessment and multidisciplinary interventions for nutritional (malnutrition-inflammation score, protein-energy wasting), physical [short physical performance battery (SPPB)] and psychological status. Results: A total of 167 patients (mean ± standard deviation age 67.8 ± 15.4 years) were screened for frailty, and 108 completed the program. At screening, 27.9% of the patients were frail, 40.0% pre-frail and 32.1% non-frail. Nutritional interventions (enrichment, oral nutritional supplements, intradialytic parenteral nutrition) resulted in stable nutritional status for most frail and pre-frail patients after 12 months. Patients following recommendations for intradialytic, home-based or combined physical exercise presented improved or stable in SPPB scores after 12 months, compared with those that did not follow recommendations, especially in the frail and pre-frail population (P = .025). A rate of 0.05 falls/patient/year was observed. More than 60% of frail patients presented high scores of sadness and anxiety. Conclusions: Frailty screening, together with coordinated interventions by nutritionists, physiotherapists, psychologists and nurses, preserved the health status of ESKD patients starting hemodialysis. Frailty assessment helped in advising patients on individual nutritional, physical or psychological needs.

7.
Clin Kidney J ; 16(11): 2254-2261, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37915938

RESUMO

Background: Dialysis patients have been maintaining a high rate of cardiovascular morbidity and mortality. For this reason, it is to introduce necessary new technical advances in clinical practice. There is a relation between toxins retention and inflammation, mortality and morbidity. Medium cut-off (MCO) membranes are a new generation of membranes that allow the removal of a greater number of medium-sized molecules compared with high-flux hemodialysis (HF-HD), but retaining albumin. MCO membranes have an increased permeability and the presence of internal filtration. Because of these special properties, MCO generated a new concept of therapy called expanded HD (HDx). Until now, online hemodiafiltration (OL-HDF) has demonstrated its superiority, in terms of survival, compared with HF-HD. However, the comparison between OL-HDF and HDx remains an unsolved question. Methods: The MOTheR HDx study trial (NCT03714386) is an open-label, multicenter, prospective, 1:1 randomized, parallel-group trial designed to evaluate the efficacy and safety of HDx compared with OL-HDF in patients treated for dialysis in Spain for up to 36 months. The main endpoint is to determinate whether HDx is non inferior to OL-HDF at reducing the combined outcome of all-cause death and stroke (ischemic or hemorrhagic), acute coronary syndrome (angina and myocardial infarction), peripheral arterial disease (amputation or revascularization) and ischemic colitis (mesenteric thrombosis). Results: The trial has already started.

8.
Nefrología (Madrid) ; 43(6): 688-702, nov.- dec. 2023. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-228007

RESUMO

La hemodiafiltración con reinfusión endógena del ultrafiltrado (HFR) es una técnica de diálisis caracterizada por un cartucho de resina con poder adsorbente que combina los mecanismos difusión, convección y adsorción en un solo esquema terapéutico. Después de cerca de 20 años de experiencia clínica con HFR, el presente artículo revisa la evidencia acumulada con esta técnica, planteando si la adición de la adsorción, como tercer mecanismo depurativo, debería ser el siguiente paso en el tratamiento de los pacientes en hemodiálisis. La HFR, a pesar de producir una extensa eliminación de toxinas urémicas, ha demostrado reducir la pérdida de nutrientes y componentes fisiológicos durante la sesión de diálisis frente a la hemodiafiltración on-line, mitigando el estado inflamatorio y el estrés oxidativo en esta población. Además de su facilidad de uso, la técnica también es altamente biocompatible y puede utilizarse en situaciones de un acceso vascular comprometido. En base a estas observaciones, la HFR parece ser una técnica especialmente útil para pacientes con elevada comorbilidad, incluyendo aquellos con fragilidad, desnutrición o enfermedad cardiovascular. En esta revisión, como panel de consenso de nefrólogos con experiencia clínica en HFR, examinamos la literatura existente y resumimos nuestros puntos de vista sobre cómo usar esta técnica, qué perfil de paciente puede ser más adecuado para la HFR, y cómo prescribir y monitorizar de manera práctica esta modalidad de diálisis (AU)


Hemodiafiltration with endogenous reinfusion of the ultrafiltrate (HFR) is a dialysis technique characterized by a resin cartridge with adsorptive properties that combines the mechanisms of diffusion, convection, and adsorption in a single therapeutic regimen. After nearly 20 years of clinical experience with HFR, this article reviews the accumulated evidence with this technique, considering whether adsorption reduction, as a third purification mechanism, should be the next step in the treatment of hemodialysis patients. HFR, beyond producing an extensive removal of uremic toxins, has demonstrated to reduce the loss of nutrients and other physiological components during the dialysis session as compared to online hemodiafiltration, ameliorating the inflammatory state and oxidative stress in this population. In addition to its ease of use, the technique is also highly biocompatible and can be used in patients with a compromised vascular access. Based on these observations, HFR appears to be an especially useful therapy for high-comorbidity patients, including those with frailty, malnutrition, or cardiovascular disease. In this review, we, as a consensus panel of nephrologists experienced with HFR, survey existing literature and summarize our views on when to use this technique, which patients may be best suited for HFR, and how to effectively prescribe and monitor this modality of dialysis in daily clinical practice (AU)


Assuntos
Humanos , Ultrafiltração/métodos , Hemofiltração/métodos , Diálise Renal/métodos
9.
Nefrología (Madrid) ; 43(6): 750-756, nov.- dec. 2023. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-228013

RESUMO

Introducción El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores (AU)


Introduction The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Soluções para Hemodiálise/química , Insuficiência Renal Crônica/terapia , Sódio/sangue , Sódio/metabolismo , Técnicas Biossensoriais
10.
Am J Nephrol ; 54(7-8): 291-298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37311444

RESUMO

INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.


Assuntos
Cloreto de Sódio na Dieta , Sódio , Humanos , Estudos Prospectivos , Diálise Renal/métodos , Dieta Hipossódica , Pressão Sanguínea , Aumento de Peso
12.
Clin Kidney J ; 16(5): 859-867, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37151418

RESUMO

Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135-141 or 134-142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.

13.
Int J Artif Organs ; 46(5): 314-317, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36932951

RESUMO

The hemoconcentration effect for middle weight solutes in hemodialysis is corrected by oversimplified methods based on hematocrit changes or distribution volume variations. Here we implemented a variable volume dual pool kinetic model targeted at obtaining a precise correction factor equation for extracellularly distributed solutes based on relevant kinetic parameters such as the ultrafiltration to dry weight ratio UF/DW, the dialyzer clearance, Kd, the intercompartment mass-transfer coefficient, Kc, and the central compartment to extracellular volume ratio, α. More than 300,000 solutions of the model were computed, performing a sweep among physiological values of the proposed kinetic parameters, resulting in a linear regression denoted by the expression fcorr = 1.0707 - 5.2246 (UF/DW) - 0.0005 Kd - 0.0004 Kc - 0.0007 α, with an excellent coefficient of determination R2 = 0.983. The presented fcorr provides a substantial extension of the currently implemented methods to estimate the hemoconcentration factor for middle and high molecular weight extracellular distributed solutes in hemodialysis.


Assuntos
Hemodiafiltração , Hemodiafiltração/métodos , Diálise Renal/métodos , Ultrafiltração , Cinética , Hematócrito
14.
Blood Purif ; 52(1): 68-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35551384

RESUMO

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Assuntos
Hemodiafiltração , Diálise Renal , Humanos , Estudos Prospectivos , Hemodiafiltração/efeitos adversos , Albuminas , Soluções para Diálise
15.
J Vasc Access ; 24(1): 155-157, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34121498

RESUMO

The following paper reports the case of a woman on in-center hemodialysis through an arteriovenous graft, who attended with an acute vascular access thrombosis. Post percutaneous thrombectomy, the patient presented a rare case of self-limited acute hepatitis secondary to the revascularization procedure. We explain the probable trigger for this complication, its pathophysiology, management, and evolution.


Assuntos
Derivação Arteriovenosa Cirúrgica , Hepatite , Trombose , Feminino , Humanos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Trombectomia/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Diálise Renal/efeitos adversos , Hepatite/complicações , Resultado do Tratamento , Estudos Retrospectivos
17.
Nephrol Dial Transplant ; 38(9): 1992-2001, 2023 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-36496176

RESUMO

BACKGROUND: In chronic haemodialysis (HD) patients, the relationship between long-term peridialytic blood pressure (BP) changes and mortality has not been investigated. METHODS: To evaluate whether long-term changes in peridialytic BP are related to mortality and whether treatment with HD or haemodiafiltration (HDF) differs in this respect, the combined individual participant data of three randomized controlled trials comparing HD with HDF were used. Time-varying Cox regression and joint models were applied. RESULTS: During a median follow-up of 2.94 years, 609 of 2011 patients died. As for pre-dialytic systolic BP (pre-SBP), a severe decline (≥21 mmHg) in the preceding 6 months was independently related to increased mortality [hazard ratio (HR) 1.61, P = .01] when compared with a moderate increase. Likewise, a severe decline in post-dialytic diastolic BP (DBP) was associated with increased mortality (adjusted HR 1.96, P < .0005). In contrast, joint models showed that every 5-mmHg increase in pre-SBP and post-DBP during total follow-up was related to reduced mortality (adjusted HR 0.97, P = .01 and 0.94, P = .03, respectively). No interaction was observed between BP changes and treatment modality. CONCLUSION: Severe declines in pre-SBP and post-DBP in the preceding 6 months were independently related to mortality. Therefore peridialytic BP values should be interpreted in the context of their changes and not solely as an absolute value.


Assuntos
Hemodiafiltração , Hipertensão , Humanos , Pressão Sanguínea , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Hemodiafiltração/métodos , Modelos de Riscos Proporcionais
18.
Nefrologia (Engl Ed) ; 43(6): 688-702, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38176980

RESUMO

Hemodiafiltration with endogenous reinfusion of the ultrafiltrate (HFR) is a dialysis technique characterized by a resin cartridge with adsorptive properties that combines the mechanisms of diffusion, convection, and adsorption in a single therapeutic regimen. After nearly 20 years of clinical experience with HFR, this article reviews the accumulated evidence with this technique, considering whether adsorption reduction, as a third purification mechanism, should be the next step in the treatment of hemodialysis patients. HFR, beyond producing an extensive removal of uremic toxins, has demonstrated to reduce the loss of nutrients and other physiological components during the dialysis session as compared to online hemodiafiltration, ameliorating the inflammatory state and oxidative stress in this population. In addition to its ease of use, the technique is also highly biocompatible and can be used in patients with a compromised vascular access. Based on these observations, HFR appears to be an especially useful therapy for high-comorbidity patients, including those with frailty, malnutrition, or cardiovascular disease. In this review, we, as a consensus panel of nephrologists experienced with HFR, survey existing literature and summarize our views on when to use this technique, which patients may be best suited for HFR, and how to effectively prescribe and monitor this modality of dialysis in daily clinical practice.


Assuntos
Hemodiafiltração , Humanos , Hemodiafiltração/métodos , Diálise Renal , Adsorção , Estresse Oxidativo
19.
Nefrologia (Engl Ed) ; 43(6): 750-756, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38242765

RESUMO

INTRODUCTION: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. MATERIAL AND METHODS: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). RESULTS: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14mmol/L with 5008 vs. 138.81mmol/L with 6008) and final plasma sodium (139.58mmol/L vs. 140.97mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1mS/cm). The ΔPNa also increased significantly. CONCLUSION: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.


Assuntos
Diálise Renal , Sódio , Humanos , Diálise Renal/efeitos adversos , Soluções para Diálise
20.
Clin Kidney J ; 15(12): 2292-2299, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36381368

RESUMO

Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, ß2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of ß2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...